GPON OLT C+++
Features
- Single fiber bi-directional data links asymmetric TX 2500Mbps/RX1250Mbps application
- 1490nm continuous-mode DFB laser transmitter and 1310nm burst-mode APD-TIA receiver
- Small Form Factor Pluggable package with SC/UPC Connector
- Single 3.3V power supply
- Digital diagnostic monitoring interface
- Low EMI and excellent ESD protection
- RoHS6 Compliance
- LVPECL compatible data input/output interface
- Class I laser safety standard IEC-60825 compliant
- LVTTL fast receiver Signal Detect (SD) indication response
- LVTTL transmitter disable control and transmitter laser fault alarm
- Digital burst RSSI function to monitor the input optical power level
Applications
- Gigabit Ethernet Passive Optical Networks (GPON)
- Gigabit-Capable Passive Optical Networks Class C+++ 60km 17~32dB attenuation range
Standards
- Complies with SFP Multi-Source Agreement (MSA) SFF-8074i
- Complies with IEEE 802.3ah
- Complies with FCC 47 CFR Part 15, Class B
- Complies with FDA 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007
- Complies with SFF-8472
- Compatible with TR-NWT-000870 4.1 ESD sensitivity classification Class2.
- Compatible with Telcordia GR-468-CORE
Specification
Absolute Maximum Ratings
|
Parameter
|
Symbol
|
Min
|
Max
|
Unit
|
Storage Ambient Temperature
|
TSTG
|
-40
|
85
|
°C
|
Storage Humidity
|
HS
|
5
|
90
|
%
|
Operating Humidity
|
HO
|
5
|
85
|
%
|
Power Supply Voltage
|
VCC
|
0
|
+3.6
|
V
|
Receiver Damaged Threshold
|
|
+6
|
|
dBm
|
Recommended Operating Conditions
|
Parameter
|
Symbol
|
Min
|
Typical
|
Max
|
Unit
|
Notes
|
Operating Case Temperature
|
Tc
|
-5
|
|
70
|
°C
|
|
-40
|
|
85
|
|
Power Supply Voltage
|
VCC
|
3.135
|
3.3
|
3.465
|
V
|
|
Supply Current
|
ICC
|
|
|
500
|
mA
|
|
Power Consumption
|
PW
|
|
|
1.65
|
W
|
|
Data Rate
|
|
|
2.5
|
|
Gbps
|
|
Electrical Characteristics
|
Parameter
|
Symbol
|
Min
|
Typical
|
Max
|
Unit
|
Notes
|
Transmitter Differential Input Voltage
|
|
300
|
|
2400
|
mV
|
|
Receiver Differential Output Voltage
|
|
500
|
|
1200
|
mV
|
LVPECL, DC Coupled
|
Transmit Fault Alarm Voltage
|
VOH
|
2.4
|
|
VCC+0.3
|
V
|
LVTTL
|
VOL
|
0
|
|
0.4
|
V
|
LVTTL
|
Transmit Disable Voltage
|
VIH
|
2
|
|
VCC+0.3
|
V
|
LVTTL
|
VIL
|
0
|
|
0.8
|
V
|
LVTTL
|
Input Differential Impedance
|
|
90
|
100
|
110
|
Ω
|
|
Transmit Disable Assert Time
|
TOFF
|
|
|
10
|
us
|
|
Loss Of Signal Voltage
|
VOH
|
2.4
|
|
VCC
|
V
|
LVTTL
|
VOL
|
0
|
|
0.4
|
V
|
LVTTL
|
Loss Of Signal Assert Time
|
TD
|
|
500
|
|
us
|
|
Loss Of Signal De-assert Time
|
TA
|
|
500
|
|
us
|
|
Optical transmitter Characteristics
|
Parameter
|
Symbol
|
Min
|
Typical
|
Max
|
Unit
|
Notes
|
Launched Power (avg.)
|
POUT
|
+7
|
|
+9
|
dBm
|
C+++
|
+5
|
|
+7
|
C++
|
+3
|
|
+5
|
C+
|
Operating Wavelength Range
|
λC
|
1480
|
1490
|
1500
|
nm
|
|
Spectral Width (-20dB)
|
∆λ
|
|
|
1
|
nm
|
|
Side Mode Suppression Ratio
|
SMSR
|
30
|
|
|
|
|
Extinction Ratio
|
ER
|
9
|
|
|
dB
|
PRBS 27-1 @1.25Gbit/s
|
Transmitter and Dispersion Penalty
|
TDP
|
|
|
2.3
|
dB
|
Transmit on 80km SMF
|
Optical Output Power after TX Disable
|
PDIS
|
|
|
-32
|
dBm
|
|
Output Eye Diagram
|
Compliant with IEEE 802.3ah
|
Transmitter Reflectance
|
|
|
|
-10
|
dB
|
|
Optical Receiver Characteristics
|
Parameter
|
Symbol
|
Min
|
Typical
|
Max
|
Unit
|
Notes
|
Wavelength Range
|
λC
|
1260
|
1310
|
1360
|
nm
|
|
Receiver Sensitivity
|
SEN
|
-29
|
|
-32
|
dBm
|
Note1
|
Optical Power Input Overload
|
SAT
|
-6
|
|
|
dBm
|
Note1
|
LOS Assert Level
|
LOSA
|
-45
|
|
|
dBm
|
|
LOS Deassert Level
|
LOSD
|
|
|
-31
|
dBm
|
|
LOS Hysteresis
|
HYS
|
0.5
|
|
6
|
dB
|
|
Receiver Reflectance
|
|
|
|
-12
|
dB
|
|
Note 1: PRBS 27-1@1.25Gbps, transmitter is operating, BER ≤1×10-10
Figure 1 RSSI TIMING SEQUENCE
RSSI Characteristics
|
Parameter
|
Symbol
|
Min.
|
Typ.
|
Max.
|
Unit
|
Notes
|
RSSI Trigger-Low
|
|
0
|
|
0.8
|
V
|
|
RSSI Trigger-High
|
|
2.0
|
|
Vcc
|
V
|
|
RSSI Trigger Delay
|
TD
|
0
|
|
3000
|
ns
|
|
Optical Signal During Time
|
TONT
|
300
|
|
|
ns
|
|
RSSI Trigger width
|
TW
|
300
|
|
TONT - TD
|
ns
|
|
I2C Access Prohibited Time
|
Tp
|
|
|
500
|
μs
|
|
Digital Diagnostic Monitoring Information
Parameter
|
Accuracy
|
Calibration
|
Note
|
Temperature
|
±3°C
|
External
|
|
Voltage
|
±3%
|
External
|
|
Bias Current
|
±10%
|
External
|
|
TX Power
|
±3dB
|
External
|
|
RX Power
|
±3dB
|
External
|
|
Note: The digital diagnostic monitoring interface defines 256-byte memory map in EEPROM, which makes use of the 8 bit address 1010001X (A2h). Please refer to the SFF-8472 Rev 10.2 for the detail information.
Pin definition
Pin
|
Name
|
Level/Logic
|
Function
|
Description
|
1
|
NC
|
NA
|
NA
|
Not
|
2
|
TX_Fault
|
LVTTL
|
TX
|
Fault
|
3
|
TX_Dis
|
LVTTL
|
Transmitter
|
Enable/Disable
|
4
|
MOD-DEF2
|
LVTTL
|
SDA
|
I2C
|
5
|
MOD-DEF1
|
LVTTL
|
SCL
|
I2C
|
6
|
MOD-DEF0
|
MOD-DEF0
|
Module
|
Definition
|
7
|
Reset
|
LVTTL
|
Receiver
|
Reset
|
8
|
SD
|
LVTTL
|
Signal
|
Detect
|
9
|
RSSI
|
Trigger
|
RSSI Trigger for Transceiver A/D
Conversion
|
High: enable RSSI A/D conversion
|
10
|
GNDR
|
NA
|
Ground
|
Receiver
|
11
|
GNDR
|
NA
|
Ground
|
Receiver
|
12
|
RD-
|
LVPECL
|
RX
|
Data-
|
13
|
RD+
|
LVPECL
|
RX
|
Data+
|
14
|
GNDR
|
NA
|
Ground
|
Receiver
|
15
|
V
|
cc
|
R
|
NA
|
16
|
V
|
cc
|
T
|
NA
|
17
|
GNDT
|
GNDT
|
Ground
|
Transmitter
|
18
|
TD+
|
LVPECL
|
TX
|
Data+
|
19
|
TD-
|
LVPECL
|
TX
|
Data-
|
20
|
GNDT
|
NA
|
Ground
|
Transmitter
|
Typical application Circuit
Figure 2 Typical Interface Circuit
EEPROM Memory Map
Figure 5 EEPROM Memory Map Specific Data Field Descriptions
EEPROM Serial ID Memory Contents
The optical transceiver contains an EEPROM. It provides access to sophisticated identification information that describes the transceiver’s capabilities, standard interfaces, manufacturer, and other information. When the serial protocol is activated, the host generates the serial clock signal (SCL, Mod Def 1). The positive edge clocks data into those segments of the EEPROM that are not writing protected within the SFP transceiver. The negative edge clocks data from the SFP transceiver. The serial data signal (SDA, Mod Def 2) is bi-directional for serial data transfer. The host uses SDA in conjunction with SCL to mark the start and end of serial protocol activation. The memories are organized as a series of 8-bit data words that can be addressed individually or sequentially.
The Module provides diagnostic information about the present operating conditions. The transceiver generates this diagnostic data by digitization of internal analog signals. Calibration and alarm/warning threshold data is written during device manufacture. Received power monitoring, transmitted power monitoring, bias current monitoring, supply voltage monitoring and temperature monitoring all are implemented. The diagnostic data are raw A/D values and must be converted to real world units using calibration constants stored in EEPROM locations 56 – 95 at wire serial bus address A2h. The digital diagnostic memory map specific data fields define as following.
EEPROM Serial ID Memory Contents (2-Wire Address A0h)
Address
|
Name of field
|
Hex
|
Description
|
BASE ID Fields
|
00
|
Identifier
|
03
|
SFP transceiver
|
01
|
Ext. Identifier
|
04
|
Serial ID module supported for SFP
|
02
|
Connector
|
01
|
SC
|
03-05
|
Transceiver Codes
|
00 00 00
|
Not defined
|
06
|
Transceiver Codes
|
80
|
BASE-PX
|
07-10
|
Transceiver Codes
|
00 00 00
|
Not defined
|
11
|
Encoding
|
01
|
8B10B
|
12
|
BR, Nominal
|
0C
|
|
13
|
Rate Identifier
|
00
|
Not defined
|
14
|
Length(9um)-km
|
14
|
20(km)
|
15
|
Length(9um)-m
|
C8
|
200(100m)
|
16
|
Length(50um)
|
00
|
Transceiver transmit distance
|
17
|
Length(62.5um)
|
00
|
18
|
Length(cable)
|
00
|
Not support cable
|
19
|
Length(OM3)
|
00
|
Not support OM3
|
20-35
|
Vendor Name
|
xx xx .... xx
|
ASCII character
|
36
|
Reserved
|
00
|
Not defined
|
37-39
|
Vendor OUI
|
00 00 00
|
Not defined
|
40-55
|
Vendor P/N
|
47 54 53 2D 53 45 54 31 31 2D 32 30 44 43(49) 2D 42(43)
|
GPON-OLT-C+++”(ASCII character)
|
56-59
|
Vendor P/N Rev.
|
41 30 20 20
|
“A0”(ASCII character)
|
60-61
|
Laser Wavelength
|
05 D2
|
1490nm
|
62
|
Reserved
|
00
|
Not defined
|
63
|
CC_BASE
|
xx
|
Check sum of bytes 0-62
|
Extended ID Fields
|
64-65
|
Options
|
00 1A
|
TX_Disable、TX_Fault and RX_LOS are implemented
|
66
|
BR,max
|
00
|
Upper bit rate margin,20%
|
67
|
BR,min
|
00
|
Lower bit rate margin,20%
|
68-83
|
Vendor SN
|
xx…..xx
|
Vendor Serial Number in ASCII character
|
84-91
|
Date Code
|
Data Code
|
Vendor Date Code in ASCII character
|
92
|
Diagnostic Monitoring Type
|
58
|
Digital Diagnostic monitoring implemented “External calibrated ” is implemented, RX measurement type is “Average Power”
|
93
|
Enhanced options
|
E0
|
Optional Alarm/warning flags, soft Tx_Disable control and monitoring, soft Tx_Fault monitoring are implemented
|
94
|
SFF-8472 compliant
|
03
|
SFF-8472 compliant with revision 10.2
|
95
|
CC-EXT
|
xx
|
Check sum of bytes 64-94
|
Vendor Specific ID Field
|
96-127
|
Vendor Specific
|
00
|
Vendor specific EEPROM
|
128-255
|
Reserved
|
00
|
Reserved for future use
|
Package Outline
(unit:mm)
Order information
Model
|
Package
|
BD-4321S-C2CDE
|
Tx1490nm, Rx1310nm , 2.5Gbps/1.25Gbps, Class C+++, >7dBm, 0C~+70C With Digital Diagnostic Monitoring
|