Description
The BAUDCOM All-In-One product is designed to provide Internet Service to subscriber’s home through the existing coaxial access network. With EPON/GPON, EOC and HFC technology , the All-In-One product meets the CATV broadcasting, VOD and Internet Service requirement of cable operators for FTTB/FTTC. It build with EPON/GPON ONU, EOC master and Optical Receiver module in one housing.
The Optical Receiver module received the optical signal from the Optical Transmitter of HFC network, and the signal processed by the PD, Amplifier, EQ and AGC to a stable RF output. The output level will be up to 108dBuv( 4*RF output) or 112dBuv (2*RF output). Ethernet data is delivered to ONU through the EPON or GPON network form the OLT.
The EOC Master module meets Home-plug AV standards, is designed based on Qualcomm AR7410 chip-set with high anti-jamming capability OFDM technology. It will modulate the Ethernet data into EOC RF signal in the 7.5-65MHz .The EOC signal and CATV signal (87~860MHz) can run on one coaxial cable without interference. The EOC Master can provide high speed data service at 600Mbps PHY Layer speed, the MAC Layer throughput is up to 320Mpbs.
Function Features
Standards
- Complies with EPON or GPON standards
- Complies with HomePlug AV international standards and IEEE 1901 Standard
Product Configuration
- Configurations available with 1 EPON or GPON ONU module
- Configurations available with 2 or 4 HomePlug AV EOC Master modules
- Configurations available with 1 HFC Optical Receiver
- Configuration available with WDM inside or not
- RF output configurations with 2 or 4 outputs
- Line Power (from 90 to 264 VAC) or Cable Line Power (60VAC) optional
- 35/47, 42/54, 65/87 type High/Low Filter optional to meet your network
CATV RF Features
- Supports higher RF output: 112dBuv@2*RF output, 108dBuv@4*RF output
- AGC (from -6 to 0dBm) function for stable RF output
Data Transportation in Coaxial Cable
- Supports data throughput of greater than 300 Mbps per EOC Master module
- Supports Max . link loss greater than 85 dB (40Mbps throughput in lab)
- Recommend 40~50dB link loss for about 300 throughput
Network Management
- CLI, SNMP management for ONU module
- WEB, SNMP management for EOC module
- Optical Receiver status monitor and control by PON system
Other Features
- IP67 Housing, aluminum alloy die casting shaping
- Line Power 60AC feed in and out


Specification
|
Item |
Parameters |
Specification |
|
Main Functional Module Configuration |
ONU |
1 x GPON or 1* EPON ONU |
|
EOC Master |
4*EOC Master |
|
|
CATV |
1 x CATV Optical Receiver with WDM or not |
|
|
External Interface |
Fiber Port |
5/8” type, 2 port, for Fiber Optic Pigtail input |
|
COM Port |
F-Type female, 4 output port for mixed EOC and CATV signal |
|
|
Power Input Port |
F-Type female, line power(40-90VAC) input version |
|
|
Power cord with China plug, |
||
|
Uplink |
Broadcast CATV (optional with WDM or not) |
With WDM version, 1*CATV/PON optical input, SC/APC, 1*PON output, SC/PC, connected with ONU input |
|
Without WDM Version, 1*CATV optical, SC/APC |
||
|
Ethernet Data (EPON or GPON optional) |
1*EPON PX20+, SC/PC (EPON Version) |
|
|
1*GPON Class B+, SC/PC (GPON Version) |
||
|
Specification of ONU Parts |
||
|
EPON |
Standard compliance |
IEEE 802.3ah |
|
Optical Interface |
1 x EPON PX20+, SC/PC |
|
|
Transmission Rate |
Upstream: 1.25Gbps, Downstream: 1.25Gbps |
|
|
Transmission Distance |
20Km@1:32 |
|
|
Optical Fiber Type |
9/125um, Single Mode, Single Fiber |
|
|
Wavelength |
Upstream 1310nm, Downstream 1490nm |
|
|
Optical Power Tx |
0dBm to 4dBm (PX20+) |
|
|
Receiving Sensitivity |
-27 dBm |
|
|
GPON |
Standard compliance |
ITU-T G.984.X |
|
Optical Interface |
1 x GPON CLASS B+, SC/PC |
|
|
Transmission Rate |
Upstream: 1.244Gbps, Downstream: 2.488Gbps |
|
|
Transmission Distance |
20Km@1:64 |
|
|
Optical Fiber Type |
9/125um, Single Mode, Single Fiber |
|
|
Wavelength |
Upstream 1310nm, Downstream 1490nm |
|
|
Optical Power Tx |
+0.5dBm to +5dBm(Class B+), +0.5dBm to +5dBm(Class C+) |
|
|
Receiving Sensitivity |
-27 dBm(Class B+), -30 dBm(Class C+) |
|
|
Indicator |
Indicator Description |
PWR: Power up or down PON:ONU registered LOS: Optical Link Status ETH: Link Status of ONU Ethernet port to EOC master |
|
Network Management |
Management Mode |
Support IEEE802.3 OAM (EPON) Support ITU-T G.984.X OMCI (GPON) Support Remote management through SNMP Suppoort Remote Management via Telnet |
|
Function |
Status monitor, Configuration management, Alarm management, Log management |
|
|
Specification of OR |
||
|
Optical Specifications |
Wavelength |
Without WDM version: 1550 nm With WDM version: 1540~1560nm (CATV), 1260-1500nm(PON) |
|
Optical Power Input Range |
-8 ~ +2 dBm |
|
|
Recommend optical Power Input Range |
-6 ~ 0dBm |
|
|
Optical Input Return Loss |
≥45 dB |
|
|
RF Specifications |
Bandwidth |
45~860 MHz |
|
Flatness |
≤±1.5 dB |
|
|
Nominal RF Output Level |
108 dBuV (4*RF Output ) |
|
|
Impedance |
75 Ohm |
|
|
Return Loss |
≥14 dB |
|
|
CNR |
≥51 dB |
|
|
CSO |
≥60 dBc |
|
|
CTB |
≥60 dBc |
|
|
Note: CNR, CSO, CTB parameter testing environment is in1550nm directly modulation transmitter, optical input -1dBm,OMI=3.2%, 59CH PAL-D signal load. |
||
|
Optical and temperatureAGC |
Stability of RF Level underoptical AGC |
≤±1 dB |
|
AGC Scope |
-6 ~ 0dBm |
|
|
LED Indicator |
Indicator Description |
OPT-L: Optical power is lower OPT-M: Optical power is nominal RF1: Status of Output 1 of optical receiver module RF2: Status of Output 2 of optical receiver module |
|
Specification of EOC Master |
||
|
Interface |
Management Port |
1 * 10/100/1000M auto-negotiation, RJ45 |
|
LED Indicator |
LED Indicator |
PWR: Power Supply Status LINK: CABLE Link Status indicator ETH1: Ethernet Ports Status connected as uplink ETH2: Ethernet Ports Status connected as downlink |
|
Performance Parameters |
RF Parameters |
Frequency Band :7.5-65MHz RF Output Level: 110±5dBuv @4 RF output port (4 EOC master version) 105±5dBuv @4 RF output port (2 EOC master version) Receive sensitivity: 45dBuv |
|
Transmission |
PHY Layer: 600Mbps Throughput on MAC Layer: 320Mbps |
|
|
Modulation Mode |
OFDM2690 carriers, 4096/1024/256/64/16/8 QAM, QPSK, BPSK, ROBO |
|
|
Working Mode |
TDMA/CSMA |
|
|
Encryption Mode |
AES-128 |
|
|
Standard |
EOC Standard |
IEEE P1901(Draft) , HomePlug AV |
|
Ethernet Standard |
IEEE 802.3, IEEE 802.3x, IEEE 802.3u IEEE802.1P, IEEE802.1Q |
|
|
Software |
Network Management |
WEB, CLI, SNMP |
|
Software Features |
VLAN, QOS, Bandwidth Control, Broadcast storm limitation |
|
|
Physical Features |
||
|
Physical Features |
Power supply |
Line Power(90-264VAC) Cable power(60VAC) optional |
|
Power Consumption |
Consumption:<45 W (4 EOC master Version) Consumption:<36 W (2 EOC master Version) |
|
|
Size |
Dimension:290×220×120mm |
|
|
Net weight |
4.2kg (4 EOC master Version) 3.7kg (2 EOC master Version) |
|
|
Environment Attribute |
Working Temperature:-20 ~ 65℃ Storage Temperature:-40 ~ 85℃ Working humidity:10% ~ 90%non-condensing Storage humidity:10% ~ 90% non-condensing |
|
Application
n CATV
n Internet Access
n VOD
n IPTV
n Camera monitor system

Order information
| Product Model |
|---|
| BD-4EOC-OR-ONU |
Payment & Security
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Estimate shipping
Refund Policy
We have a 30-day return policy, which means you have 30 days after receiving your item to request a return.
To be eligible for a return, your item must be in the same condition that you received it, unworn or unused, with tags, and in its original packaging. You’ll also need the receipt or proof of purchase.
To start a return, you can contact us at support@baudcom.com.cn. Please note that returns will need to be sent to the following address: Room 519A, Building A, Lianming Rd 389, Minhang District, Shanghai, China
You can always contact us for any return question at support@baudcom.com.cn.
Damages and issues
Please inspect your order upon reception and contact us immediately if the item is defective, damaged or if you receive the wrong item, so that we can evaluate the issue and make it right.
Exceptions / non-returnable items
Certain types of items cannot be returned, like custom products (such as special orders or personalized items). Please get in touch if you have questions or concerns about your specific item.
Unfortunately, we cannot accept returns on sale items or gift cards.
Exchanges
The fastest way to ensure you get what you want is to return the item you have, and once the return is accepted, make a separate purchase for the new item.
European Union 14 day cooling off period
Notwithstanding the above, if the merchandise is being shipped into the European Union, you have the right to cancel or return your order within 14 days, for any reason and without a justification. As above, your item must be in the same condition that you received it, unworn or unused, with tags, and in its original packaging. You’ll also need the receipt or proof of purchase.
Refunds
We will notify you once we’ve received and inspected your return, and let you know if the refund was approved or not. If approved, you’ll be automatically refunded on your original payment method within 10 business days. Please remember it can take some time for your bank or credit card company to process and post the refund too.
If more than 15 business days have passed since we’ve approved your return, please contact us at info@baudcom.com.cn.