BD-POW-01 Mini-Designed Optical Power Meter is a self-developed test instrument The fiber power meter is widely used for installation, operation and maintenance of fiber-optic network. This fiber optic power meter can test optical power within the range of 800~1700nm wave length. There are 850nm, 1300nm, 1310nm, 1490nm, 1550nm, 1625nm, six calibrated wavelength. As the fiber optic power meter, we supply the power optical meter to global.

| 1. wavelength | 
| 2. Optical power value | 
| 3. Optical power unit | 
| 4.battery level | 
| 5.Automatic shutdown symbol | 
| 6. On / off key | 
| 7. Wavelength selection | 
| 8. Relative mode measurement | 
| 9.Absolute mode measurement | 
| 10.detector | 
 Products Feature 
|   | Compact and portableDurable and easy to carry More convenient to use | 
|  | Six Kinds Wavelength 850nm、1300nm、1310nm 1490nm、1550nm、1625nm   | 
|  | The measurement is accurate and the error is controlled within 0.5dbmOptical power tester built by rigorous science and technology | 
 Instructions

Common faults and Solutions
| Fault performance | Possible causes | resolvent | 
| Weak LCD display | Insufficient power supply | Replace the battery | 
| The backlight cannot be lit | Insufficient power supply | Replace the battery | 
| No display after startup | Insufficient power supply/others | Replace the battery/ Reboot | 
| Unable to power on | Insufficient power supply | Replace the battery | 
| The LCD display remains unchanged | Insufficient power supply | Replace the battery | 
| The LCD display data remains unchanged or weak | The optical adapter connector is faulty or dirty | Check whether the optical adapter connector is correct; Clean the sensor end face | 
 BD-POW-01-A:
 Measurement range: -70~+10dBm,
calibrated wavelength:850nm、1300nm、1310nm、1490nm、1550nm、1625nm
 BD-POW-01-C:
 Measurement range: -50~+26dBm,
calibrated wavelength:850nm、1300nm、1310nm、1490nm、1550nm、1625nm
 Specifications
| Measurement range dBm | -70~+10 dBm | -50~+26 dBm | 
| Wavelength range(nm) | 800~1650 | 
| 850nm、1300nm、1310nm、1490nm、1550nm、1625nm | 
| Calibrated wavelength | (other wavelength will be on request) | 
| Detector | Inga As | 
| Accuracy | <±3% (-10dBm、22℃) | 
| Resolution | Linearity:0.1%,Non-linearity:0.01dBm | 
| Working temperature | -10℃~+50℃ | 
| Storage temperature | -20℃~+70℃ | 
| Relative humidity | 90%(+30℃), | 
| connector | Two types: | 
| 1. FC/PC connector; | 
| changeable FC/PC SC/PC( ST and LC as Optional) | 
| Power supply | 3pcs AAA batteries | 
| DC power supply | Support wide range power input work (AC 90-240) | 
| Working hours | >120 hours(without backlight) | 
| Weight(g) | 160g | 
| Dimension(mm) | 130×63×29 | 
 
Order Information
| BD-POW-01-A | Optical Power Meter, 850/1300/1310/1490/1550/1625nm, measuring range -70 to +10 dBm, FC/SC connector. | 
| BD-POW-01-C | Optical Power Meter, 850/1300/1310/1490/1550/1625nm, measuring range -50 to +26 dBm, FC/SC connector. |